8 tons of ice machine standard - cooling method: "water cooling (can be determined as air cooling)".
8 tons of ice machine standard working conditions - ambient temperature 25 ° C, water supply temperature 15 ° C, evaporator temperature -22 ° C, condenser temperature 40 ° C.
Maintenance knowledge of 8 tons of ice machine - cleaning the inner wall of the evaporator once every 2 months and cleaning the water tray, water tank, water pump, salt water pump and salt water tank for 15 days.
10 tons of ice machine standard - cooling method: "water cooling (can be determined as air cooling)".
Standard operating conditions of 10 tons of ice machine - ambient temperature 25 ° C, water supply temperature 15 ° C, evaporator temperature - 22 ° C, condenser temperature 40 ° C.
Maintenance knowledge of 10 tons of ice machine - cleaning the inner wall of the evaporator once every 2 months and cleaning the water tray, water tank, water pump, salt water pump and salt water tank for 15 days.